ABOUT THIS PRODUCT:

The PathoSEEK® The Bile Tolerant Gram Negative (BTGN) Detection Assay is used in combination with PathoSEEK Amplification Mix (included) and SenSATIVAx® DNA Purification Kits (purchased separately) to detect species of bacteria that can survive in the human stomach and are potentially harmful to humans.


PathoSEEK Detection Assays are multiplex tests based on gene amplification and detection by quantitative PCR. Each PathoSEEK Detection Assay contains primers and probes specific for the target species as well as an internal control. The target organisms will be read on the following fluorophores:

  • Internal Control - HEX
  • BTGN - FAM


Compatible with the following instruments:

  • BMS Mic qPCR Cycler
  • Agilent AriaMx Real-Time PCR instrument
  • BioRad CFX96


Other required reagents:

  • SenSATIVAx® DNA Purification Kit
  • BTGN / Coliform / Entero Positive Control

Details

All Medicinal Genomics reagents are manufactured in a facility certified to ISO 9001 standards.

All lots of reagents are functionally tested in-house, and Certificates of Analysis (COAs) are available upon request.

Please contact support@medicinalgenomics.com if you have any questions or concerns.


FEATURES

Fast and scalable workflow

  • Same-day results
  • Turnkey automation is available with leading liquid handling systems
  • Multiplex assays maximize instrument capacity


Validated for Use on Multiple Matrices

  • Cannabis/Hemp flower
  • Oil
  • Chocolate
  • Candies
  • Stainless steel
  • And more!


Advantages Over Culture Methods

  • Results in hours, not days!
  • Better reproducibility of results
  • Easily automated with liquid handling robotics


DISCLAIMER

This test was developed, and its performance characteristics determined by Medicinal Genomics Company, for laboratory use. Any deviations from this protocol are not supported by MGC.


This test has not been validated on remediated (irradiated, ozone treated, acid treated, hydrogen peroxide treated, etc.) samples. Samples that have undergone remediation may cause discordant results between plating methods and PathoSEEK methods. When remediated samples produce a result above the action limit on qPCR, we recommend confirming viability with an approved plating method.